To read a load ring rating correctly, you need to identify its working load limit (WLL). You should also check the unit and confirm that the rating applies to the way you’re using the ring.
But many riggers read the WLL and stop there. At RUD Australia, we’ve seen this lead to overloaded lifts, particularly when crews overlook loading direction or the wider lifting setup.
We’ve created this guide to help you avoid these mistakes. You’ll learn what the rating means, how pull direction changes it and what to check before you lift.
What the Load Ring Rating Tells You

A load ring’s rating tells you how much weight it can safely lift under the conditions it’s designed for. That figure is its working load limit.
For example, a load ring with a WLL of 2.5 tonnes and a 4:1 safety factor has a breaking strength of 10 tonnes. This means it can withstand four times its rated working load before breaking. However, you must still limit the lift to 2.5 tonnes. The higher figure doesn’t increase the ring’s rated lifting capacity.
The ring must also be free from cracks and other damage that could weaken it. That’s why RUD crack-tests every VLBS weld-on ring electromagnetically before it leaves the factory. You can request a test certificate, though you’ll still need to inspect the ring before each lift.
How to Read the Rating on a Load Ring

Reading the rating takes two steps. The first is on the ring, and the second is in how you use it.
1. Check the Number and Its Unit
Start by looking for the WLL stamped on the load ring. Its location depends on the model, but you’ll usually find it on the base or on the ring itself.
Once you’ve found it, read the number and the unit beside it. Ratings are usually in tonnes, so a stamp reading 2.5 means 2.5 tonnes, or 2,500 kg. Compare that with your load’s weight before you go any further.
Then find the model name beside the number. It tells you whether you’re holding a weld-on ring like RUD’s VLBS or a bolt-on ring like the VLBG. That decides which figure in the manufacturer’s table applies to your lift, which the next section covers.
2. Match the Rating to How the Ring Is Used
The stamped number is the ring’s WLL, but that figure doesn’t necessarily apply to every loading direction. Some models have a lower rating when the force comes from the side than when it pulls straight up. So the same ring may lift a heavier load when you position it correctly.
To position it correctly, first check how the ring moves. Many load rings have a pivoting bracket, so you can turn the ring to face the pull. Some models can even swivel while carrying a load. Just make sure the bracket moves freely, because resting on the load’s edge can stop it from lining up.
Next, check the manufacturer’s WLL table for your model (usually in the data sheet). It lists the rating for each condition, like a straight vertical lift or a sling leg at an angle. An angled leg pulls the ring sideways, which is why its rating can differ, so use the figure that matches your lift.
Temperature can change the rating too. The bolt loses some strength as it gets hot, so the manufacturer lowers the WLL for high-temperature use, and the data sheet shows by how much.
Common Mistakes When Reading Load Ring Ratings
You might ask how anyone misreads a number stamped right on the ring. It happens, though. In fact, we’ve seen lifts stopped and re-rigged because crews overlooked important details when checking load ring ratings. These three mistakes are particularly easy to make:
- Assuming All Load Rings Have the Same Rating: Two rings can look almost identical but have different WLLs because of differences in design, thread size, material and intended application. That’s why you should always check the exact model before selecting a replacement or estimating its capacity.
- Forgetting the Rest of the Lift: Inspect every component between the hook and the load, including slings, shackles and connecting hardware. And always work to the lowest-rated component. Safe Work Australia’s General Guide for Cranes also emphasises selecting slings that suit the load.
- Trusting Worn or Unreadable Markings: Check the stamp is legible before every lift, since paint, grime and wear can hide it. If you can’t read it, keep the ring off the job until the data sheet or the manufacturer confirms the rating.
Notice that some of these mistakes have nothing to do with reading the number itself. You can identify the correct WLL and still make the wrong choice if you overlook the components or conditions around it.
When the Rating Isn’t Clear
Sometimes the stamp is worn away or doesn’t match what you expected. In that case, there’s one thing to avoid and one thing to do.
Don’t Guess From Size or Appearance
A larger ring isn’t automatically rated for a heavier load, and the same applies when replacing an existing lifting point.
A replacement bolt that fits the thread isn’t necessarily suitable for the application. Some products use manufacturer-specific bolts or other components you can’t swap for standard hardware.
RUD’s VLBG-PLUS range, for example, uses a captive, exchangeable ICE-Bolt with specific material and design properties. Choosing a visually similar bolt wouldn’t establish that it meets the original product requirements.
Check the Manufacturer’s Documentation
Tag the ring out of service until you’ve confirmed what it is. Your lifting equipment register, inspection records or purchase invoices often list the model.
Once you’ve identified the product, look for its technical data sheet, catalogue entry or installation instructions. These documents provide the information you need to confirm the following:
- WLL
- Thread specifications
- Approved loading directions
- Temperature limits
- Installation requirements
If you can’t identify the product or find a specification that matches your application, contact the manufacturer.
A Quick Check Before You Rely on the Rating
By now, you should have a clear picture of how to read a load ring rating and where crews slip up. Still, it’s worth running this quick checklist before your next lift:
- Exact Model: Confirm you’ve identified the manufacturer and the exact model.
- Working Load Limit: Lift no more than the WLL, never the breaking load.
- Loading Conditions: Match the rating to your pull direction, temperature and setup.
- Rest of the Rig: Confirm that the bolt is tightened to the specified torque or the weld meets the installation instructions. Then confirm the sling and other hardware can take the load.
- Wear and Markings: Make sure the stamp is legible, and the ring shows no cracks, damage or wear.
If any of these checks raise a question, don’t proceed based on an estimated rating. Refer to the manufacturer’s instructions or have the equipment assessed by a competent person.
Need help identifying the right lifting point? Contact RUD Australia to discuss your application and get advice on the appropriate load ring and its specifications.
Frequently Asked Questions
A few practical questions come up when choosing and using load rings. Here are quick answers to the ones most likely to affect your setup.
How Does Sling Angle Affect the Load on Two Lifting Points?
The wider the sling angle, the more force each lifting point takes. Two 2.5-tonne rings don’t simply provide 5 tonnes of capacity at every sling angle. Check the manufacturer’s load table for the correct angle.
How Long Should the Bolt Be on a Bolt-On Load Ring?
For steel, aim for thread engagement at least equal to the bolt’s diameter. Softer materials such as aluminium may require more. Always follow the manufacturer’s specified requirements.
Can You Fit a Metric Load Ring Into an Inch Thread?
No. The load ring’s thread must match the threaded hole. Never force a metric ring into an inch thread or vice versa.
Read More : EV Charging Station Dimensions: How Much Space a Workplace Parking Lot Really Needs